Secondary Containment Automatic Day Tank

UL-142 Secondary Containment Automatic Day Tanks

OPTIONS

LAST UPDATE April 19, 2001.
CONSULT YOURLOCAL REPRESENTATIVE OR THE FACTORY FOR YOUR CURRENT NET PRICING.

TABLE OF CONTENTS

SLIM TANKS EXTRA TANK CONNECTIONS STANDARD COLORS
PUMPS COVERS DELETION OPTIONS
MOTORS VALVES PUMPING UNITS
DUAL PUMP & MOTOR BASINS PUMP AND MOTOR ON BASE PLATE
HAND PUMPS FUEL OIL COOLERS LOCAL CODE REQUIREMENTS
MECHANICAL OPTIONS ELECTRICAL OPTIONS  
FUEL STRAINERS IMMERSION HEATERS  
VENTS FUEL RETURN TANKS  
EMERGENCY PRESSURE RELIEF VENTS FUEL RETURN PUMP AND MOTOR  

SLIM TANKS

UL LISTED

UL Listed

MODEL GAL/LIT W x D x H (inches)
DT10 Slim ULD 10/38 24 x 12 x 22
DT15 Slim ULD 15/57 24 x 12 x 25.5
DT25 Slim ULD 25/95 24 x 12 x 33
DT50 Slim ULD 50/180 36 x 12 x 42
DT60 Slim ULD 60/228 36 x 12 x 47
DT75 Slim ULD 75/284 36 x 12 x 55
DT100 Slim ULD 100/379 48 x 12 x 55
DT150 Slim ULD 150/570 72 x 12 x 55
DT200 Slim ULD 200/760 96 x 12 x 55

back to top


SLIM ECONOMY DAY TANKS

MODEL GAL/LIT W x D x H (inches)
ET10 Slim ULD 10/38 24 x 12 x 14
ET15 Slim ULD 15/57 24 x 12 x 17.5
ET25 Slim ULD 25/95 24 x 12 x 25
ET50 Slim ULD 50/180 36 x 12 x 34
ET60 Slim ULD 60/228 36 x 12 x 39
ET75 Slim ULD 75/284 36 x 12 x 47
ET100 Slim ULD 100/379 48 x 12 x 47
ET150 Slim ULD 150/570 72 x 12 x 47
ET200 Slim ULD 200/760 96 x 12 x 47


back to top


SLIM FUEL TANKS

MODEL GAL/LIT W x D x H (inches)
FT10Slim ULD 10/38 24 x 12 x 14
FT15 Slim ULD 15/57 24 x 12 x 17.5
FT25 Slim ULD 25/95 24 x 12 x 25
FT50 Slim ULD 50/189 36 x 12 x 34
FT60 Slim ULD 60/228 36 x 12 x 39
FT75 Slim ULD 75/284 36 x 12 x 47
FT100 Slim ULD 100/379 48 x 12 x 47
FT150 Slim ULD 150/570 72 x 12 x 47
FT200 Slim ULD 200/760 96 x 12 x 47

back to top


PUMPS

2 GPM
100A
Pump, 2 GPM High lift Gear 10 GPM
100D
Pump, 10 GPM High lift Gear, Requires a 3/4 HP motor.
4 GPM
100B
Pump, 4 GPM High lift Gear 100E Pump, 20 GPM Highlift Gear, Requires a 1 HP Motor
7 GPM
100C
Pump, 7 GPM High lift Gear, Requires a 1/2 HP motor.    

back to top


MOTORS

120 Motor, HP, 12 VDC 157 Motor, HP, 380 VAC, 3 phase, 50 Hz. Includes option #380 & #386
121 Motor, HP, 24-28 VDC 152 Motor, HP, 115 VAC, 1 phase, 60 Hz. Includes option #382
119 Motor, HP, 115 VAC, 1 phase, 60 Hz.(Standard with DT) 158 Motor, HP, 115 VAC, 1 phase, 50 Hz Includes option #382
126 Motor, HP, 115 VAC,1 phase, 50 Hz. 159 Motor, HP, 230 VAC, 1 phase, 60 Hz. Includes options #380 & #386
128 Motor, HP, 230 VAC, 1 phase, 60 Hz. Includes option #380 & #384 160 Motor, HP, 220 VAC, 1 phase, 50 Hz. Includes options #380 & #386
129 Motor, HP, 220 VAC, 1 phase, 50 Hz. Includes option #380 & #384 135 Motor, HP, 230 VAC, 3 phase, 60 Hz. Includes options #380 & #386
130 Motor, HP, 230 VAC, 3 phase, 60 Hz. Includes options #380 & #386 136 Motor, HP, 220 VAC, 3 phase, 50 Hz. Includes Options #380 & #386
134 Motor, HP, 220 VAC, 3 phase, 50 Hz. Includes options #380 & #386 155 Motor, HP, 460 VAC, 3 phase, 60 Hz. Includes options #380 & #386
133 Motor, HP, 460 VAC, 3 phase, 60 Hz. Includes option #380 & #386 137 Motor, HP, 380 VAC, 3 phase, 50 Hz. Includes options #380 & #386
132 Motor, HP, 380 VAC, 3 phase, 50 Hz. Includes options #380 & #386 115 Motor, 1 HP, 115 VAC, 1 phase, 60 Hz. Includes option #382
144 Motor, HP, 115 VAC, 1 phase, 60 Hz. Includes option #382 116 Motor, 1 HP, 115 VAC, 1 phase, 50 Hz. Includes option #382
147 Motor, HP, 115 VAC, 1 phase, 50 Hz. Includes option #382 117 Motor, 1 HP, 230 VAC, 1 phase, 60 Hz. Includes option #380 & #384
148 Motor, HP, 230 VAC, 1 phase, 60 Hz. Includes option #380 & #384 118 Motor, 1 HP, 220 VAC, 1 phase, 50 Hz. Includes option #380 & #384
149 Motor, HP, 220 VAC, 1 phase, 50 Hz. Includes option #380 & #384 138 Motor, 1 HP, 230 VAC, 3 phase, 60 Hz. Includes option #380 & #386
150 Motor, HP, 230 VAC, 3 phase, 60 Hz. Includes option #380 & #386 139 Motor, 1 HP, 220 VAC, 3 phase, 50 Hz. Includes option #380 & #386
156 Motor, HP, 220 VAC, 3 phase, 50 Hz. Includes option #380 & #386 161 Motor, 1 HP, 460 VAC, 3 phase, 60 Hz. Includes option #380 & #386
153 Motor, HP, 460 VAC, 3 phase, 60 Hz. Includes option #380 & #386 162 Motor, 1 HP, 380 VAC, 3 phase, 50 Hz. Includes option #380 & #386

back to top


DUAL PUMP & MOTOR

127A Dual Pump and Motor Assembly. Adds second float switch and 2 GPM pump and 1/3 HP, 120 VAC motor. First pump starts at 86% usable fuel. Second pump starts at 82% usable fuel. Both pumps stop at 100% usable fuel. Other start stop levels can be specified. Used to double the pumping capacity for periods of high fuel consumption. Complete with press to test toggle switch and red pump running light.
127B Dual Pump and Motor Assembly. Two float switches, one closing at 86% of usable fuel capacity, the second closing at 82% of usable fuel capacity. Both pumps stop at 100%usable fuel with automatic transfer switch to automatically alternate each pump and motor to the lead starting position complete with pump run-off-automatic toggle switch and red pump running light.
127C Dual Pump and Motor Assembly. Manual duplex system similar to option 127B, but with manual transfer switch.

back to top


HAND PUMPS

Piston Hand Pump
166
Auxiliary Hand Pump, Piston type. 20 gallon per 100 strokes. Self primes to 20'' of lift. Hand pump check valve and motor-pump check valve included. Rotary Hand Pump
167
Auxiliary Hand Pump, Rotary type. 10 gallons per 100 revolutions. Self primes to 20'' of lift. Hand pump check valve and motor-pump check valve included.

back to top


MECHANICAL OPTIONS

201A Manual Fuel Fill, 2" NPT Locking, Mounted on FT inspection plate 228A Pipe Stand Adaptor for DT10, 15, 25. Raises tank above floor.
201B Manual Fuel Fill, 2" NPT Locking, Mounted on tank 228B Pipe Stand Adaptor for DT50, 60, 75, and 100
201C Manual Fuel Fill, 3" NPT, Locking, Mounted on tank 228C Pipe Stand Adaptor for DT200, 275
201D Manual Fuel Fill, 4" NPT, Locking, Mounted on tank 226B Sight Glass with Guard with check valves at top & bottom
205 Wall Mounting Bracket for 10, 15, & 25 gallon tank    

back to top


FUEL STRAINERS

215 Fuel Strainer, 1" NPT, spin on type, 10 GPM capacity, shipped loose
216A Fuel Strainer, 1" NPT, Simplex, Shipped loose
216B Fuel Strainer, 1-1/2" NPT, Simplex, Shipped loose
216C Fuel Strainer, 2" NPT, Simplex, Shipped loose
217A Fuel Strainer, 1" NPT, Duplex, Shipped loose
217B Fuel Strainer, 1-1/2" NPT, Duplex, Shipped loose
217C Fuel Strainer, 2" NPT Duplex, Shipped loose

back to top


VENTS

220A Vent cap, 1" NPT, "T" Type, Double outlet vent, with stainless steel wire screen, female 221B Vent Cap, 1-1/4" NPT, Mushroom Type, Single outlet vent, with stainless steel wire screen, female
220B Vent cap, 1-1/4" NPT, "T" Type, Double outlet vent, with stainless steel wire screen, female 221C Vent Cap, 1-1/2" NPT Mushroom Type, Single outlet vent, with stainless steel wire screen, female
220C Vent Cap, 1-1/2" NPT, "T" Type, Double outlet vent, with stainless steel wire screen, female 221D Vent Cap, 2" NPT, Mushroom Type, Single outlet vent, with stainless steel wire screen, female
220D Vent Cap, 2" NPT, "T" Type, Double outlet vent, with stainless steel wire screen, female 221E Vent Cap, 3" NPT, Mushroom Type, Single outlet vent, with stainless steel wire screen, female
220E Vent Cap, 3" NPT, "T" Type, Double outlet vent, with stainless steel wire screen, female 221F Vent Cap, 4" NPT, Mushroom Type, Single outlet vent, with stainless steel wire screen, female

back to top


EMERGENCY PRESSURE RELIEF VENTS

222A Emergency Pressure Relief Vent, 2" NPT, Emergency relief vent, set at 8 oz/sq in. male
222B Emergency Pressure Relief Vent, 3" NPT, Emergency relief vent, set at 8 oz/sq in. male
222C Emergency Pressure Relief Vent, 4" NPT, Emergency relief vent, set at 8 oz/sq in. male
222D Emergency Pressure Relief Vent, 5" NPT, Emergency relief vent, set at 8 oz/sq in. male
222E Emergency Pressure Relief Vent, 6" NPT, Emergency relief vent, set at 8 oz/sq in. male


back to top


EXTRA TANK CONNECTIONS

230F Connection, 1/4" NPT, Tank flange, 1/4" NPT, welded to tank 230C Connection, 1-1/2" NPT, Tank flange, 1-1/2" NPT, welded to tank
230 Connection, 3/8" NPT, Tank flange, 3/8" NPT, welded to tank. 230D Connection, 2" NPT, Tank flange, 2" NPT, welded to tank
230 Connection, 1/2" NPT, Tank flange, 1/2" NPT, welded to tank 230E Connection, 3" NPT, Tank flange, 3" NPT, welded to tank
230 Connection, 3/4" NPT, Tank flange, 3/4" NPT, welded to tank 230G Connection, 4" NPT, Tank flange, 4" NPT, welded to tank
230A Connection, 1" NPT, Tank flange, 1" NPT, welded to tank 230H Connection, 5" NPT, Tank flange, 5" NPT, welded to tank
230B Connection, 1-1/4" NPT, Tank flange, 1-1/4" NPT, welded to tank    


back to top


COVERS

234A Cover, 24" x 12" x 8", Single pump & motor 235A Cover, Weather Proof, 24" x 12" x 8", Single pump & motor
234B Cover, 24" x 18" x 8", Dual pump & motor 235B Cover, Weather Proof, 24" x 18" x 8", Dual pump & motor
234C Cover, 24" x 18" x 10", Dual pump & motor 235C Cover, Weather Proof, 24" x 18" x 10", Dual pump & motor
234D Cover, 24" x 26" x 10", Dual pump & motor 235D Cover, Weather Proof, 24" x 26" x 10", Dual pump & motor


back to top


VALVES

240 Valve, drain petcock, 3/8" NPT, Replaces threaded plug in bottom of tank 260E Valve, Solenoid, 1" NPT, 120 VAC. For optional 20 GPM pump
240 Valve, drain petcock, 1/2" NPT, Replaces threaded plug in bottom of tank 265A Valve, Solenoid, 3/8" NPT, DC. For standard 2 GPM pump
245 Valve, Drain, Nominal 10 gallons per minute. Manual valve to gravity drain day tank to main tank using existing plumbing 265B Valve, Solenoid, 3/8" NPT, DC. For optional 4 GPM pump
250 Valve, Drain, Emergency for remote actuation. Nominal 10 gallons per minute. Signaled valve gravity drains day tank to main tank using existing plumbing. Indicator light on tank illuminates and pump motor disconnects 265C Valve, Solenoid, 1/2" NPT, DC. For optional 7 GPM pump
255A Valve, Check, 3/8" NPT, Installed on pump intake to prevent loss of prime 265D Valve, Solenoid, 3/4" NPT, DC. For optional 10 GPM pump
255B Valve, Check, 1/2" NPT 265E Valve, Solenoid, 1" NPT, DC. For optional 20 GPM pump
255C Valve, Check, 3/4" NPT 270 Valve, Manual Cut Off, 1/2" NPT
255D Valve, Check, 1" NPT 270 Valve, Manual Cut Off, 1" NPT
260A Valve, Solenoid, 3/8" NPT, 120 VAC, Installed on pump intake to prevent loss of pump prime or tank flooding. For standard 2 GPM pump 272 Switch, Low Flow, With alarm relay wired to terminal switch
260B Valve, Solenoid, 3/8" NPT, 120 VAC. For optional 4 GPM pump 275 Valve, Foot, 1" NPT, To prevent loss of pump prime
260C Valve, Solenoid, 1/2" NPT, 120 VAC. For optional 7 GPM pump 280 Valve, Pressure Relief. For any motor driven pump
260D Valve, Solenoid, 3/4" NPT, 120 VAC. For optional 10 GPM pump 282 Priming Tee. Consists of pump priming tee, fuel line, priming tee and check valve


back to top


BASINS

285A Rupture Basin, DT10 Open top, 150% capacity 285P Rupture Basin, DT700
285T Rupture Basin, DT15 285Q Rupture Basin, DT800
285B Rupture Basin, DT25 285R Rupture Basin, DT900
285C Rupture Basin, DT50 285S Rupture Basin, DT1000
285U Rupture Basin, DT60 285AS Rupture Basin, DT10 Slim. Open top, 150% of slim tank specified
285D Rupture Basin, DT75 285TS Rupture Basin, DT15 Slim
285E Rupture Basin, DT100 285BS Rupture Basin, DT25 Slim
285F Rupture Basin, DT150 285CS Rupture Basin, DT50 Slim
285G Rupture Basin, DT200 285US Rupture Basin, DT60 Slim
285H Rupture Basin, DT275 285DS Rupture Basin, DT75 Slim
285V Rupture Basin, DT300 285ES Rupture basin, DT100 Slim
285I Rupture Basin, DT325 285FS Rupture Basin, DT150 Slim
285J Rupture Basin, DT350 285GS Rupture Basin, DT200 Slim
285K Rupture Basin, DT400 288 Rupture Basin, Weather Proof
285L Rupture Basin, DT450 290 Rupture Basin Float Switch, 120 VAC, With relay, Stops motor
285M Rupture Basin, DT500 290B Rupture Basin Float Switch, 120 VAC, Contact leads terminate in " connection box.
285N Rupture Basin, DT550 295 Terminals for remote signal of option #290
285O Rupture Basin, DT600    


back to top


FUEL OIL COOLERS

298A Fuel Oil Cooler, 6,500 BTU/HR. 3 GPM nominal flow, 3 psi pressure drop at 3 GPM, with 1/3 HP, 115 volt, 1 phase motor 298E Fuel Oil Cooler, 62,000 BTU/HR. 13 GPM nominal flow, 3 psi pressure drop at 13 GPM with 1/3 HP, 115 volt, 1 phase motor
298B Fuel Oil Cooler, 11,000 BTU/HR. 6 GPM nominal flow, 3 psi pressure drop at 6 GPM, with 1/3 HP, 115 volt, 1 phase motor 298F Fuel Oil Cooler, 62,000 BTU/HR. 13 GPM nominal flow, 3 psi pressure drop at 13 GPM with 1/2HP, 230 volt, 3 phase motor
298C Fuel Oil Cooler, 22,000 BTU/HR. 8 GPM nominal flow, 3 psi pressure drop at 8 GPM, with 1/3 HP, 115 volt, 1 phase motor 298G Fuel Oil Cooler, 110,000 BTU/HR. 28 GPM nominal flow, 3 psi pressure drop at 28 GPM with 3/4 HP, 115 volt, 1 phase motor
298D Fuel Oil Cooler, 38,000 BTU/HR. 16 GPM monimal flow, 3 psi pressure drop at 16 GPM, with 1/3 HP, 115 volt, 1 phase motor 298H Fuel Oil Cooler, 110,000 BTU/HR. 28 GPM nominal flow, 3 psi pressure drop at 28 GPM with 3/4 HP, 230 volt, 3 phase motor


back to top


ELECTRICAL OPTIONS

300 Pilot Light, Amber. 120 VAC Indicates power available 315 Float Valve. Replaces basic float switch.
301 Pilot Light, Red. 120 VAC. Indicates low fuel level in remote main storage tank. Signal by others. 316A Circuit Breaker, DC. Mounted on tank. For DC motors.
302 Three Position Toggle Switch. Pump run/off/auto. Replaces press to test switch 316B Circuit Breaker, AC. Mounted on tank. For 1 phase AC motors
303 Low Fuel Level Alarm, 120 VAC. Float switch activates red light on control panel at 84% of usable fuel. 316C Circuit Breaker, AC. Mounted on tank. For 3 phase AC motors
304 Low Fuel Level Alarm, 120 VAC. Float switch activates red light on control panel at 84% of usable fuel capacity. With relay, with relay contacts wired to terminal strip for remote alarm. Relay contacts rated 10 amp. 317 Float Switch, Standard
305A Low Fuel Level Alarm, 120 VAC. Float switch activates relay at 84% of usable fuel. No light on control panel. Relay contacts wired to terminal strip for remote alarm. Relay contacts rated 10 amp. 325 Alarm, Switch Not in Auto. Flashing yellow light.
305B Low Fuel Level Alarm Float switch activates at 84% of usable fuel, wired to terminal strip. No light or relay on control panel. Contacts rated 10 watt, 0.08 amp. 326 Remote Fill Panel. NEMA-3R enclosure, for remote mounting. At 90% fuel fill, alarm horn activates and light illuminates; at 95%, alarm activates, Light illuminates, and optional solenoid valve closes allowing no more fuel to enter tank. Includes alarm horn, silence switch, low fuel level light, and on-off switch.
306 Critical Low Fuel Alarm, 12/24/VDC. Float switch activated red light on control panel. With relay, with relay contacts wired to terminal strip for remote alarm and engine shutdown. Relay contacts rated 10 amp. Prevents loss of engine fuel prime. Operates from engine battery. 380 Control Transformer, 50 KVA, 480/240/208-120 VAC, for control panel and relays.
307 High Fuel Level Alarm, 120 VAC. Float switch activates red light on control panel at 103% of usable fuel. 382 Contactor, 1 Pole Power relay, 1 phase, to start 120 volt motors.
308 High Fuel Level Alarm, 120 VAC. Float switch activates red light on control panel at 103% of usable fuel. With relay, with relay contacts wired to terminal strip for remote alarm. Relay contacts rated 10 amp. 384 Contactor, 2 Pole Power relay, 1 phase, to start 230 volt 1 phase motors.
309A High Fuel Level Alarm, 120 VAC. Float switch activates relay at 103% of usable fuel. No light on control panel. Relay contacts wired to terminal strip for remote alarm. Relay contacts rated 10 amp. 386 Contactor, 3 Pole Power relay, 3 phase, to start 3 phase motors.
309B High Fuel Level Alarm, 120 VAC. Float switch activates at 103% of usable fuel, wired to terminal strip. No light or relay on control panel. Contacts rated 10 watt, 0.08 amp. 388 Contactor, 2 Pole Motor starter, with overload trip relay, to start 1 phase motors.
310 High/Low Fuel Level Alarm, 120 VAC. Float switch activates red light on control panel at 103% high and 84% low of usable fuel. 390 Contactor, 3 Pole Motor starter, with overload trip relay, to start 3 phase motors.
311 High/Low Fuel Level Alarm, 120 VAC. Float switch activates red light on control panel at 103% high and 84% low of usable fuel. With relay, with relay contacts wired to terminal strip for remote alarm. Relay contacts rated 10 amp. 392A Disconnect, 2 Pole, Fused 240 volt, 30 amp.
312A High/Low Fuel Level Alarm, 120 VAC. Float switch activates relay at 103% high and 84% low of usavle fuel. No light on control panel. Relay contacts wired to terminal strip for remote alarm. Relay contacts rated 10 amp. 392B Disconnect, 3 Pole, Fused 240 volt, 30 amp.
312B High/Low Fuel Level Alarm, 120 VAC. Float switch activates at 103% high and 84% low of usable fuel, wired to terminal strip. No light or relay on control panel. Contacts rated 10 watt, 0.08 amp. 392C Disconnect, 3 Pole, Non-fused 600 volt, 30 amp
313 Critical High Fuel Level Alarm and Shutdown, 120 VAC. Float switch activates red light on control panel. With relay, with relay contacts wired to terminal strip for remote alarm. Relay contacts rated 10 amp. Also stops the pump motor and includes a solenoid valve mounted on fuel inlet. Solenoid valve closes, preventing further fuel from entering tank. Complies with NFPA #37. 392D Disconnect, 3 Pole, Fused 600 volt, 30 amp
314 Float Switch, Explosion Proof Replaces basic float switch. 318 Float Switch, DPDT. Replaces standard float switch.


back to top


IMMERSION HEATERS

319A Immersion Heater, 250 Watts, with Thermostat 1" NPT, 120 volt, low watt density, with extra 1" NPT connection. 10-85 gallon. Low fuel level alarm w/relay advised 319D Immersion Heater, 750 Watts, with Thermostat 1" NPT, 120 volt, low watt density, with extra 1" NPT connection. Low fuel alarm w/relay advised.
319B Immersion Heater, 350 Watts, with Thermostat 1" NPT, 120 volt, low watt density, with extra 1" NPT connection. 100-150 gallon. Low fuel level alarm w/relay advised. 319E Immersion Heater, 1000 Watts, with Thermostat 1" NPT, 120 volt, low watt density, with extra 1" NPT connection. Low fuel alarm w/relay advised.
319C Immersion Heater, 500 Watts, with Thermostat 1" NPT, 120 volt, low watt density, with extra 1" NPT connection. 200-400 gallon. Low fuel level alarm w/relay advised. 319F Immersion Heater, 1500 Watts, with Thermostat 1" NPT, 120 volt, low watt density, with extra 1" NPT connection. Low fuel level alarm w/relay advised.


back to top


FUEL RETURN TANKS

STANDARD FEATURES
Heavy duty construction
Reverse pump & motor action
Fuel return dip tube
Heavy duty low action float switch
MODEL GAL/LIT LIST PRICE
DT10R 10/38 951.00
DT15R 15/57 975.00
DT25R 25/95 1,015.00


back to top


FUEL RETURN PUMP & MOTOR

170 Fuel Return Pump & Motor Assembly Includes float switch, 2 GPM bronze high lift gear pump with stainless steel shaft and HP, 115 VAC, 1 phase, 60 Hz. motor, and pump suction dip tube. Reverse acting pump and motor return fuel to primary tank


back to top


STANDARD COLORS AVAILABLE

400A Hospital White 400I Kohler Gold
400B Caterpillar Yellow 400J Waukesha Orange
400C Caterpillar Tan 400K Air Force Blue
400D Cummins Desert Beige 400L Kohler Creme
400E Onan Green 400M Gloss Black
400F GM Alpine Green 400N E&CA; Gray
400G Cummins Old Gold 400S Special Paint
400H Kohler Blue    


back to top


DELETION OPTIONS

X100A Delete Pump
X119 Delete Motor
X119 Delete Motor, Float Switch wired to optional solenoid valve
X119 Delete Motor, Float Switch wired to relay. Relay wired to terminal strip for remote signal
X224 Delete Fuel Level Gauge
X317 Delete Float Switch


back to top


PUMPING UNITS

SA-01374 Remote Pumping Unit, Standard pump and motor in NEMA-1 housing SA-01461 Local Pumping Unit, Standard pump and motor in NEMA-1 housing, for mounting on skid tank
SA-01749 Dual Remote Pumping Unit, Standard pump and motor in NEMA-1 housing SA-01603 Dual Local Pumping Unit,
Standard pump and motor in NEMA-1 housing, for mounting on skid tank


back to top


PUMP & MOTOR ON BASEPLATE

Pump Motor on Base
SA-01684 2 GPM pump w/ HP motor SA-01686 10 GPM pump w/ HP motor
SA-01685 4 GPM pump w/ HP motor SA-01687 20 GPM pump w/ 1 HP motor
SA-01675 7 GPM pump w/ HP motor    


back to top


LOCAL CODE REQUIREMENTS

CITY OF CHICAGO: Requires, but is not limited to the following:
UL Listed and Labeled Tank
285 Rupture Basin, 150%
290 Rupture Basin Float Switch
296 Dip Tube Assembly, Pump Suction
296 Dip Tube Assembly, Fuel Return
UL Listed Industrial Components
313 Critical High Fuel Level Alarm and Pump Shut Down
304 Low Fuel Level Float Switch
325 Flashing Yellow Light, Hand/Off/Auto Switch, Not in Auto
CITY OF NEW YORK: Requires, but is not limited to the following:
286 Rupture Basin, 200%

STATE OF MASSACHUSETTS: Requires, but is not limited to the following:
Nameplate stating: Manufacturer, Capacity, Gauge Steel, Serial Number, and Date Manufactured.
STATE OF WISCONSIN: Requires, but is not limited to the following:
UL Listed Double Wall Day Tank or Generator Base Tank
Outdoor installation must be bullet-proof.
CITY OF LOS ANGELES: Requires, but is not limited to the following:
UL Listed and Labeled Tank
304 Low Fuel Level Float Switch
308 High Fuel Level Float Switch
326 Remote Fill Panel, NEMA 3R enclosure, for remote mounting. At 90% fuel fill, alarm horn activates and light illuminates; at 95%, alarm activates, light illuminates, and optional solenoid valve closes allowing no more fuel to enter tank. Includes alarm horn, silence switch, low fuel level light, and on-off switch.
201B Manual Fuel Fill, 2" NPT Locking
215 Fuel Strainer, 1" NPT, Spin on Type
240 Valve, Drain Petcock
260 Valve, Solenoid, 120 VAC
166 Auxiliary Hand Pump, Piston Type
296 Dip Tube Assembly, Fuel Suction
296 Dip Tube Assembly, Fuel Return
CITY OF HOUSTON: Requires, but is not limited to the following:
UL Listed and Labeled Tank

LAST UPDATE APRIL 18, 2000. CONSULT YOUR LOCAL REPRESENTATIVE OR THE FACTORY FOR YOUR CURRENT PRICE
Home | Day Tanks | Generator Base Tanks | Meter Panels | Enclosures| Pump Sets | Literature | Local Reps | Site Map | Contact Us